Spacing of Multiple Culverts

Spacing between multiple culverts

Spacing of multiple metals culverts is specified by the AASHTO LRFD Bridge Design Specifications, Section 12, “Buried Structures,” like this:

Type of Structure Minimum Distance Between Pipes (ft)
Round Pipes
< 2.0 1.0
2.0 – 6.0 Diameter/2
> 6.0 3.0
Pipe Arches
< 3.0 1.0
3.0 – 9.0 Span/3
9.0 – 16.0 3.0
Arches
All Spans 2.0

The Canadian Highway Bridge Design Code, Section 12, “Buried Structures,” specifies minimum spacing of multiple culverts like this:

7.5.6 Minimum clear spacing between conduits

For multi-conduit structures, including soil-metal structures with shallow corrugations, the minimum clear spacing between adjacent conduits shall be not less than 1000 mm or one-tenth of the largest span;  this requirement may be waived for concrete boxes with cement grout between the boxes.  For multi-conduit soil-metal structures with deep corrugations, the minimum clear spacing between adjacent conduits shall be 1000 mm;  if CLSM is used between the conduits, the minimum clear spacing may be reduced to 800 mm if the CLSM is poured to a height where its width is at least 800 mm.

 